MSoft reconstruction does not happen
This does not apply to version 4.0 of MSoft onwards.
When MSoft is reconstructing a 3D file, it is possible that
it stops during the process.
If that happens, the PoissonRecon.exe file must be replaced.
The file is located by default at this location :
C:\Program Files\Qwadra\MSoft\ExternalProcesses\
Rename the existing PoissonRecon.exe to something different.
It is recommended to rename it PoissonReconSneaky.exe.
Next up, download this file to replace the PoissonRecon.exe
that was renamed
Add the file provided by the link above to where you renamed
the previous version of PoisonRecon.exe.
Close the folder. MSoft should work normally. If MSoft still
does not work, please contact us for further assistance.
Still need help?
Related Articles
Bad reconstruction in MSoft
What is a bad reconstruction? When treating a scan in MSoft, it is possible that the reconstruction is not done properly by the software. A bad reconstruction is easily identifiable by the result, frequently resulting in an indistinct mass, as shown ...
BodyScan unrecognized by MSoft
In case MSoft stops recognizing the BodyScan, it is advised to test the scanner at each possible step. These steps serve as a way to find the root of the issue, as well as diagnose whether the BodyScan and its cable are defective or not. While the ...
Changing environment variables for MSoft
Please note that this operation is not required for versions 3.16 of MSoft and onwards. To properly use the EinScan H scanner along with MSoft, you might need to change the environment variables of your computer. To do so, please follow these steps: ...